Voltron 7.5KVA Solar Hybrid Inverter

1,258,700.00

Voltron 7.5KVA Solar Hybrid Inverter(VT3500-7.5K-Pro)

Category:

Power range 7.5KVA
24V/48VDC input voltage
Powerful charge rate up to 65Amp
Inbuilt pure copper transformer
Pure sine wave output
LED+LCD display
MPPT solar charge controller 60A
MPPT efficiency max 98%
50/60Hz automatic sensing
RS232 with free CD
Battery priority function
Automatically send signal to start generator
DC start & automatic self-diagnostic function
High efficiency design & “Power Saving Mode” to
conserve energy
MODEL
: PV35-7.5K Pro

Default Battery System Voltage:
48VDC

INVERTER OUTPUT

Continuous
output power :
7.5KVA/6.0KW

Surge rating (20ms):
18.0KW

Capable Of Starting
Electric Motor: 3HP

Output waveform :
Pure sine wave/ same as input (bypass
mode)

Inverter Efficiency(Peak)
: >88%

Line mode efficiency :
>95%

Power factor :
1.0

Nominal output voltage:
RMS 220V/230V/240VAC(+/-10%
RMS)

Output frequency:
5OHz/60Hz +/-0.3 Hz

Short circuit protection:
Yes (1sec after fault)

Typical transfer time:
10ms(max) 10ms(max)

AC INPUT

Voltage:
230VAC

Selectable Voltage Range:
155~280VAC(For Personal Computers)

Frequency Range:
50HZ/60HZ (Auto sensing)
40~80Hz

BATTERY

Minimum start voltage :
20.OVDC/21.0VDC for24VDC mode (40.OVDC/42.0VDC for 48VDC
mode)

Low battery alarm :
21.0VDC+/-0.3V for 24VDC mode (42.OVDC+/-0.6V for
48VDC mode)

Low battery Cutoff :
20.0VDC+/-0.3V for 24VDC mode (40.OVDC+/-0.6V for
48VDC mode)

High voltage alarm :
32.0VDC+/-0.3V for 24VDC mode (64.OVDC+/-0.6V for
48VDC mode)

High battery voltage
recover: 31.0VDC+/-0.3V for 24VDC
mode (62.OVDC+/-0.6V for 48VDC mode)

Idle consumption-search
mode: <25W when power saver on CHARGER Output voltage : Depends on battery type Charger AC input breaker rating: 40A Max charge power rate: 1/3 Rating power Overcharge protection S.D.: 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) Maximum Charge Current: 40A BTS Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature BYPASS & PROTECTION Input voltage waveform : Sine wave (grid or generator) Nominal voltage: 220V/230V/240VAC Max input AC voltage: 300VAC for 230VAC HV mode Nominal input frequency: 50Hz or 60Hz Overload protection (SMPS load): Circuit breaker Output short circuit protection: Circuit breaker Bypass breaker rating : 40A Max bypass current 40Amp Rated voltage: 24VDC/48VDC PV open circuit voltage: Operational max = 145VDC temperature corrected VOC SOLAR CHARGER Maximum PV Charge Current : 60A DC Voltage: 48V Maximum PV Array Power: 3200W MPPT Range @ Operating Voltage: 64~145VDC Maximum PV Array Open Circuit Voltage: 147VDC Maximum Efficiency: >98%

Standby Power Consumption:
<2W

MECHANICAL SPECIFICATIONS

Mounting :
Wall mount

Inverter dimensions
(W*H*D):
587*414*211mm

Inverter weight (solar
chg) KG: 60+2.5

Shipping
dimensions(W*H*D):
750*520*310mm

Shipping weight (solar
chg) KG: 62+2.5

OTHER

Operation
Temperature Range: 0�C to
40�C

Storage
Temperature: -15�C to
60�C

Audible
Noise: 60dB MAX

Display:
LED+LCD

Standard warranty:
1 year