Power range 10KVA
24V/48VDC input voltage
Powerful charge rate up to 65Amp
Inbuilt pure copper transformer
Pure sine wave output
LED+LCD display
MPPT solar charge controller 60A
MPPT efficiency max 98%
50/60Hz automatic sensing
RS232 with free CD
Battery priority function
Automatically send signal to start generator
DC start & automatic self-diagnostic function
High efficiency design & “Power Saving Mode” to
conserve energy
MODEL
: PV35-10K Pro
Default Battery System Voltage: 48VDC
INVERTER OUTPUT
Continuous output power :
10KVA/8.0KW
Surge rating (20ms):
24.0KW
Capable Of Starting Electric Motor:
4HP
Output waveform :
Pure sine wave/ same as input (bypass mode)
Inverter Efficiency(Peak):
>88%
Line mode efficiency :
>95%
Power factor :
1.0
Nominal output voltage:
RMS 220V/230V/240VAC(+/-10% RMS)
Output frequency:
5OHz/60Hz +/-0.3 Hz
Short circuit protection:
Yes (1sec after fault)
Typical transfer time:
10ms(max) 10ms(max)
AC INPUT
Voltage: 230VAC
Selectable Voltage Range:
155~280VAC(For Personal Computers)
Frequency Range:
50HZ/60HZ (Auto sensing) 40~80Hz
BATTERY
Minimum start voltage :
20.OVDC/21.0VDC for24VDC mode (40.OVDC/42.0VDC for 48VDC mode)
Low battery alarm :
21.0VDC+/-0.3V for 24VDC mode (42.OVDC+/-0.6V for 48VDC mode)
Low battery Cutoff :
20.0VDC+/-0.3V for 24VDC mode (40.OVDC+/-0.6V for48VDC mode)
High voltage alarm :
32.0VDC+/-0.3V for 24VDC mode (64.OVDC+/-0.6V for 48VDC mode)
High battery voltage
recover: 31.0VDC+/-0.3V for 24VDC mode (62.OVDC+/-0.6V for 48VDC mode)
Idle consumption-search mode:
<25W when power saver
on
CHARGER
Output voltage :
Depends on battery type
Charger AC input breaker
rating: 40A
Max charge power rate:
1/3 Rating power
Overcharge protection
S.D.: 31.4VDC for 24VDC mode (62.8VDC
for 48VDC mode )
Maximum Charge Current:
70A
BTS
Continuous output power
Yes Variances in charging voltage & S.D. voltage base
on the battery temperature
BYPASS &
PROTECTION
Input voltage waveform :
Sine wave (grid or generator)
Nominal voltage:
220V/230V/240VAC
Max input AC voltage:
300VAC for 230VAC HV mode
Nominal input frequency:
50Hz or 60Hz
Overload protection (SMPS
load): Circuit
breaker
Output short circuit
protection: Circuit
breaker
Bypass breaker rating
: 50A
Max bypass
current
80Amp
Rated voltage:
24VDC/48VDC
PV open circuit voltage:
Operational max = 145VDC temperature corrected
VOC
SOLAR CHARGER
Maximum PV Charge Current
: 60A
DC Voltage:
48V
Maximum PV Array Power:
3200W
MPPT Range @ Operating
Voltage:
64~145VDC
Maximum PV Array Open
Circuit Voltage:
147VDC
Maximum Efficiency:
>98%
Standby Power Consumption:
<2W
MECHANICAL SPECIFICATIONS
Mounting :
Wall mount
Inverter dimensions
(W*H*D):
587*414*211mm
Inverter weight (solar
chg) KG: 60+2.5
Shipping
dimensions(W*H*D):
750*520*310mm
Shipping weight (solar
chg) KG: 62+2.5
OTHER
Operation
Temperature Range: 0�C to
40�C
Storage
Temperature: -15�C to
60�C
Audible
Noise: 60dB MAX
Display:
LED+LCD
Standard warranty:
1 year